| Ultraviolet/Germicidal
water purification systems |
Ultraviolet/Germicidal
water purification systems
from Hanovia... |
...provide
a fast, unique way to disinfect
water without heat or chemicals.
Using short-wave radiation
from Hanovia germicidal ultraviolet
lamps, STERITRON purifiers
destroy all water-borne microorganisms,
including bacteria and viruses.
Hanovia germicidal lamps are
found in a variety of applications,
including personnel protection
and prevention and prevention
of cross infection in hospitals,
laboratories and veterinary
facilities and product contamination
prevention in the food processing,
pharmaceutical, bottling,
electronics and semiconductor
industries.
|
| How
the system operates: |
|
|
|
| • |
Water
enters purifier and flows into annular
space between quartz sleeve and
outside chamber wall. |
| • |
Wiper
segments induce turbulence in flowing
liquid to ensure uniform exposure
of suspended microorganisms to lethal
ultraviolet rays. |
| • |
Translucent
sight port provides positive indication
of germicidal lamp operation |
| • |
Wiper
assembly facilitates periodic cleaning
of quartz sleeve without disassembly
or interruption of purifier operation.
|
| • |
Water
leaves purifier ready for use instantly.
|
| |
|
|
|
Simple
installation and maintenance |
| • |
Install
purifier as close
as possible to the
location in which
it is to be used.
|
| • |
Connect
inlet and outlet to
water supply. |
| • |
Plug
into grounded electrical
outlet. |
| • |
Maintain
by cleaning quartz
sleeve with manual
wiper once every month
- more frequently
where indicated by
application conditions. |
| • |
Recommended
lamp replacement:
Once every 10,000
hours of operation(approximately
14 months of continuous
operation). |
|
|
|
| |
| HANOVIA
ultraviolet/germicidal lamp specifications: |
STERITRON
water purifiers deliver optimum performance
when equipped with the following specially
designed HANOVIA lamps. These HANOVIA
low-pressure type lamps produce the germicidal
rays needed for water purification with
maximum efficiency and the added benifit
of low power requirements. These lamps
eliminate the posibility of overheating
and the need for special equipment to
deal with overheating. |
| |
| Lamp
No. |
Purifier
Model No. |
Nominal
Lamp
Length |
Power
Consumption
(1) |
Ultraviolet
Output
(2) |
Rated
Effective
Life |
| 9009A481 |
31946.001 |
8
15/16" (227mm) |
10
Watts |
2.4
Watts |
10,000
Hrs |
| 9012A481 |
31946.101 |
11
7/8" (302mm) |
14
Watts |
3.7
Watts |
10,000
Hrs |
| 9018A481 |
31946.201 |
17
3/4" (451mm) |
20
Watts |
6.5
Watts |
10,000
Hrs |
| 9034A481 |
31946.301 |
33
7/8" (860mm) |
39
Watts |
14
Watts |
10,000
Hrs |
| 9046A481 |
31946.401 |
45
7/8" (1165mm) |
50
Watts |
19.3
Watts |
10,000
Hrs |
| 9047A481 |
31946.501 |
46
1/4" (1175mm) |
110
Watts |
45
Watts |
10,000
Hrs |
|
| |
| • |
Wattage
is lamp watts only and does not
include ballast loss. |
| • |
Maximum
rated output at 254 nanometers. |
|
| |
 |
| |
| Organism |
Type |
Ailment/Symptom |
**mu**Wsec/cm2 |
| Streptococcus |
Bacteria |
Strep
Throat |
3,800 |
| Dysentery
Bacilli |
Bacteria |
Diarrhea |
4,200 |
| Influenza |
Virus |
Flu |
6,600 |
| Staphylococcus |
Bacteria |
Boils |
6,600 |
| Fecal
Coliform |
Bacteria |
Diarrhea |
6,600 |
| Salmonella |
Bacteria |
Food
Poisoning |
10,000 |
| Legionella
Pneumophila |
Bacteria |
Legionnaires'
Disease |
12,300 |
| Bacteriophage(E.
Coli) |
Virus |
Diarrhea |
6,600 |
|
| |
| Lethal
Exposure Times: |
| • |
The
dosage necessary to inactivate a
microorganism is a product of time
and intensity.
|
| • |
When
used as directed, STERITRON purifiers
will provide a dosage in excess
of 30,000 microwatt seconds per
square centimeter (**mu**Wsec/cm2).
|
| • |
Ultraviolet
energy at 254nm is required for
complete destruction of some microorganisms. |
|
| |
| Standard
Model Specifications: |
| Model |
GPM |
GPH |
Inlet
and
(5)
Outlet
Size |
Repla-
cement
Lamp(s) |
Power(6)
Consu-
mption |
Length |
Width |
Height |
Gross
Wt. |
Net
Wt. |
Cu.
Ft. |
| 31946.001 |
2 |
120 |
1/2"
NPT |
9009A481 |
14
Watts |
16
3/8" |
5
1/2" |
8
5/16" |
10
lbs. |
7
lbs. |
1.1 |
| 31946.101 |
3 |
180 |
3/4"
NPT |
9012A481 |
18
Watts |
19
3/8" |
5
1/2" |
8
3/16" |
11
lbs. |
8
lbs. |
1.2 |
| 31946.201 |
6 |
360 |
3/4"
NPT |
9018A481 |
24
Watts |
25
3/8" |
5
1/2" |
8
3/16" |
16
lbs. |
11
lbs. |
1.5 |
| 31946.301 |
12 |
720 |
1"
NPT |
9034A481 |
44
Watts |
39
3/4" |
5
1/2" |
8
3/16" |
27
lbs. |
20
lbs. |
3.3 |
| 31946.401 |
20 |
1,200 |
1
1/2" NPT |
9046A481 |
54
Watts |
52
3/8" |
5
1/2" |
8
3/16" |
35
lbs. |
26
lbs. |
4.3 |
| 31946.501 |
40 |
2,400 |
2"
NPT |
9047A481 |
140
Watts |
50" |
8" |
13" |
51
lbs. |
38
lbs. |
7.5 |
| 31946.601
(1) |
83 |
5,000 |
2"
NPT |
9047A481
(2 Lamps) |
280
Watts |
50" |
22" |
16" |
116
lbs. |
85
lbs. |
15 |
| 31946.701
(2) |
166 |
10,000 |
2"
NPT |
9047A481
(4 Lamps) |
560
Watts |
50" |
22" |
33" |
267
lbs. |
174
lbs. |
37 |
| 31946.801
(3) |
250 |
15,000 |
2"
NPT |
9047A481
(6 Lamps) |
840
Watts |
50" |
22" |
50" |
400
lbs. |
263
lbs. |
57 |
| 31946.901
(4) |
333 |
20,000 |
2"
NPT |
9047A481
(8 Lamps) |
1,120
Watts |
50" |
22" |
67" |
534
lbs. |
352
lbs. |
77 |
|
| |
| • |
Two
31946.501s connected in series,
1 inlet and 1 outlet.
|
| • |
Two 31946.601s
connected in parallel, 2 inlets
and 2 outlets. |
| • |
Three
31946.601s connected in parallel,
3 inlets and 3 outlets. |
| • |
Four 31946.601s connected
in parallel, 4 inlets and 4 outlets. |
| • |
All inlets and outlets
are male pipe threads. |
| • |
Total power consumption,
including ballast loss |
| |
| - |
Maximum
recommended operating pressure
for all purifiers is 100 PSI
|
| - |
Pressure
drop at maximum recommended
flow rate is 5 PSI or less
|
| - |
All
data shown above are for 118
volt 60 Hz. Units are also
available for 220 volt 50
Hz and 12 volt DC operation.
|
|
|
| |
| Steritron
water purification systems give you all
these benifits: |
| • |
STERITRON
disinfection is lethal to all microorganisms.
|
| • |
Effluent
is guaranteed to exceed United States
Public Health Standards for bacterial
purity. |
| • |
Economically
purifies hundreds of gallons of
water for each penny of operating
costs. |
| • |
Safe operation with
no danger of overdosing and no addition
of dangerous chemicals. |
| • |
No chlorine taste. |
| • |
Easy installation and
simple maintenance. |
| • |
Space-saving compact
units. |
| • |
Choice of continuous
or intermittent disinfection automatically. |
| • |
Water ready for use
the instant it leaves the purifier.
|
| • |
Corrosion-free stainless
steel chamber, head, clamp and hardware. |
| • |
Easy-off retainer cap
for quick lamp change with no tools,
water pressure shutdown or draining
of tank. |
| • |
Simple disassembly.
|
| • |
No special tools needed
if repairs become necessary. |
|
| |